What is UPS and Circuit Layout

What Is UPS ?
UPS Means :Uninterruptible power supply 
ups provide backup some time .Sudden power failure stops the computer. Thereby, may be impaired computer software and hardware.
The power to the UPS backup works for some time.
There are two types of UPS.
  • Online Ups
  • Offline Ups
how it works and Block Diagram

Block diagram of (UPS) Offline
offline Ups Works two Mode:
  1. Ac to Ac Mode
  2. Dc to Ac Mode
  • Ups Circuits
  • Filter cicuit
  • AVR (automatic voltage regulatory) circuit
  • Charging circuit
  • Protection, overload, battery low indicate circuit
  • Dc to Ac Circuit
  • Output Socket
Battery Charging :

If charge battery in 18 volt ----- Boost Charge
If charge battery in 15 volt ----- Semi Boost charge
If charge battery in 13.5 volt ----- Trickle charge

Main Parts of UPS:

Battery => 7 Amp., 12 volt for UPS
                 20 Amp, 12 volt for inverter

Step Down transformer

6-0-6 / 9-09 /for ups
6-0-6 / 9-09 / 12-0-12 / for inverter

Switching Component

Power Transistor (metal body) 3055/3773

Mosfet
IRF 244N/45N, P55N06,P50N06,7N70,6N60

IRF 150/630/550/540//650

IGBT(Insulated Gate Bipoler Trasnsistor)+Mosfet

Kit 
According to VA of ups or Inverter

Cabinet,Switch,Fuse,Wire,Etc.


Faults Findind of UPS 

AC Mode Related Fualts

Ups works in Dc mode but does not works in AC mode?
First of all check Input  Impidence(by multi-meter).it should not be full or nill.

If full deflection, then short circuit check input wire,line filter circuit,and check step down transformer.

If nill  deflection ,then open circuit,check such as input wire,fuse,switch and step down txfr.

input impidence   is ok, then check ac volt available on first relay or input relay. If ac volt is ok then check relay,its coil supply and coil connected circuit such as diode,polar capacitor,related /connected Ic and its supply .